For homes, businesses and construction[email protected]0180 201 111

Wiring and materials · Prepare for your electrician

Dutch cable types: VD, XMvK, YMvK and underground cable

VD wire, XMvK, YMvK and YMvK-as often appear beside each other in Dutch shops. They are not interchangeable. A family name indicates something about construction, while the complete datasheet defines the properties of an individual product.

Netherlands · revision copy-1 · A17 · 06/10/2026

What this guide covers

Start with the intended use: an existing conduit route, a new indoor installation or a supply through the garden. Have the cable family, conductor count and cross-section specified before ordering. A familiar name or a discounted reel does not establish suitability.

The material-length tool accompanying this guide therefore calculates metres only. It does not select conductor size or assess voltage drop, fault withstand or protective devices. Have those decisions recorded before choosing among products with similar names. No. Check the manufacturer’s data for the exact product. Colour is not a reliable selection method.

Different types of installation wire and cable
Illustration
Copy or print your summary

Start with the intended use: an existing conduit route, a new indoor installation or a supply through the garden. Have the cable family, conductor count and cross-section specified before ordering. A familiar name or a discounted reel does not establish suitability.

What the four names describe

VD installation wire is an individually insulated conductor. Its construction differs from a cable containing several insulated cores within an outer sheath. Nexans specifies conduit or a similar closed system for its H07V-U/H07V-R Eca installation wires.

XMvK is a light installation-cable family. TKF describes its XMvK Eca for fixed individual connections. Check the exact product's restrictions, including bundling, heat and exposure.

YMvK is an installation-cable family with different product applications. For example, Nexans publishes a particular construction and fire classification for YMvK Dca ULTIMO. Those properties cannot be assigned to every grey cable.

YMvK-as and related underground-cable constructions have a different build. A specific product may permit direct burial: TKF states this for the linked VO-YMvKas model. That does not settle the route, protection, terminations or protective-earth arrangement.

Read beyond the family name

Check the datasheet for:

  • the full designation and manufacturer part number;
  • core count and conductor colours or functions;
  • conductor cross-section in mm² and conductor class;
  • outside dimensions and bending or installation restrictions;
  • moisture, sunlight, temperature and mechanical properties;
  • fire classification and the relevant declaration of performance.

A value in mm² describes a conductor's cross-sectional area. It is not the outside diameter of the complete cable. An additional sheath or screen can increase the cable's overall size without changing the chosen conductor area.

Check how any earth conductor or screen is identified in the description. A shortened shop title cannot establish which protective conductor is present or how it must be terminated.

How is the conductor size chosen?

The required size depends on more than the appliance's power rating. Length, protection, installation method, surrounding conditions and other factors affect the assessment. Prysmian lists several design inputs for cable calculation.

The material-length tool accompanying this guide therefore calculates metres only. It does not select conductor size or assess voltage drop, fault withstand or protective devices. Have those decisions recorded before choosing among products with similar names.

Avoid treating the dimensions of an old cable as proof of what the replacement should be. The previous installation may have different loads, conditions or unresolved defects.

Prepare a useful order schedule

  1. Describe the equipment being supplied and record its manufacturer information.
  2. Draw the complete route, including vertical sections and termination points.
  3. Record the conditions along each part: indoors, outdoors, in conduit, through insulation or in the ground.
  4. Have the electrical specification and termination method confirmed.
  5. Calculate the required length and compare suitable purchase quantities.

For a conduit system, count the separate conductors according to the agreed schedule. For a multicore cable, measure the length of the complete cable. Keep agreed termination allowances visible. Deduct only existing stock that is identifiable, serviceable and suitable for the design.

A reel-size calculation cannot compensate for a route that has not been surveyed. Keep any uncertain section marked separately and resolve it before ordering cut-to-length material.

Include the associated materials

A complete list may include conduit, supports, boxes, glands, connectors and identification. For a ground route, the ground conditions, protection and accessible terminations also need attention. The design determines those items and quantities; one reel and two boxes will not be a complete kit for every project.

After confirming the specification, compare cables at Elektramat or underground-cable categories at HORNBACH. Check the exact variant before purchase. An “outdoor cable” category is not proof of direct-burial suitability.

Frequently asked questions

Is 2.5 mm² always correct for a socket circuit?

No. The installation and its conditions determine the required specification. A commonly sold size is not a universal design rule.

Is grey cable automatically underground cable?

No. Check the manufacturer’s data for the exact product. Colour is not a reliable selection method.

Can I use leftover cable?

Only when its type, condition, length and origin are sufficiently known and it suits the confirmed design.

Would you like the material choice checked first? Discuss the route and application with CAS. Mention any cable you already own without assuming it must be used.

Outside diameter in mm and copper cross-section in mm² are different measurements
Outside diameter in mm and copper cross-section in mm² are different measurements

Materials and specifications

Before buying, check that the size, type and specification suit your installation. Use the article list and tools to work out the quantities you need.

Tape measure and plan

Tape measure
Illustration
Quantity and unit
One tape measure and current plan
Specification
Survey accessible surfaces only; measurements do not establish electrical suitability.

Manuals and model details

Quantity and unit
One current manual per exact product
Specification
Use exact model/revision, with conflicting instructions unresolved until manufacturer/installer clarification.

Installation wire or cable

Specified by the electrician
Quantity and unit
Separate measured quantities per complete specification
Specification
Conductor material/class/cross-section, colours, insulation, installation method and product approval; never infer from wattage alone.

Cable for a designed underground route

Specified by the electrician
Quantity and unit
Designed route and termination allowances
Specification
Exact cable application, mechanical protection, route/soil/installation conditions and professional design.

Plan route quantities

Keep each material, colour and cross-section separate. Specification is still required. A total is not a cutting plan, continuous reel length or conduit-fill calculation. Allowances and contingency are your planning choices, not installation rules.

Worked example and formula

4.2 + 2.8 + 1.5 m plus two 0.3 m allowances = 9.1 m. With a user-chosen 10% contingency: 10.01 m. A 4 m light line and 1.2 m supply route stay separate.

planned m = (sum of measured m + explicit allowances m) × (1 + contingency / 100)

Formula version 2026-10-05.1

Material route 1
Stays on this device during this visit.

One length per line, in metres (0–1000 m). Do not separate a list with commas.

Stays on this device during this visit.
Stays on this device during this visit.
For example 2.5. Up to 2 decimal places; no thousands separators.

Sources

Would you like CAS to carry out the work?

Tell us about the room, equipment and changes you need. Agree the work, checks and warranty terms before the job starts.

Discuss the work

In the event of fire or immediate danger: move to safety and call 112. Do not wait for a form reply.