16 or 19 mm electrical conduit: what determines the choice?

Larger conduit offers more space, but choosing between 16 and 19 mm also involves the conductors, bends, boxes and installation method. Measure the proposed route first and have the complete system specified. A chart giving a number of wires per tube is not a complete electrical design.

Netherlands · revision copy-1 · A16 · 06/10/2026

What this guide covers

You can draw the route and count materials from a confirmed plan. Selecting the conductors, permissible fill and electrical arrangement needs a technical assessment.

TKF separates rigid and flexible conduit in its example table. This illustrates why one figure found online cannot apply to every product. Do not treat an example as permission to pull more wires into an existing route. No. It adds material lengths from your entries. Permissible fill and electrical suitability need separate technical assessment.

Electrical conduits in two diameters with couplers
Illustration
Copy or print your summary

You can draw the route and count materials from a confirmed plan. Selecting the conductors, permissible fill and electrical arrangement needs a technical assessment.

The label does not state the free internal space

Dutch conduit packaging can show both millimetres and traditional inch descriptions. For example, Martens specifies a 19 mm outside diameter for a product labelled 3/4 inch. Use the product dimensions instead of calculating your own conversion from the trade description.

The usable internal space also depends on wall thickness and construction. Flexible and smooth conduit with the same nominal size should not automatically be treated as equivalent.

Check the interfaces of bends, couplers, supports and boxes. Pipelife describes systems using 16, 19 and 20 mm interfaces. A component labelled 20 mm is not automatically a replacement for an existing 19 mm part.

Why there is no single wire-count answer

Technical selection needs the actual outside dimensions of the insulated conductors, conduit construction, bends and route. Heat dissipation and the chosen installation method also need consideration.

TKF separates rigid and flexible conduit in its example table. This illustrates why one figure found online cannot apply to every product. Do not treat an example as permission to pull more wires into an existing route.

Factory-prewired conduit has its own specified construction. It does not prove that the same conductor combination suits every other tube with that nominal outside diameter. Confirm its suitability for the proposed installation.

Draw the route first

  1. Mark the start, end and all connection points.
  2. Measure horizontal and vertical sections separately.
  3. Show bends, branches and wall or floor penetrations.
  4. Record the supporting material, access and possible moisture or sunlight exposure.
  5. Have the route and system confirmed before chasing, drilling or ordering.

Include walls that will be closed after the installation. Connection accessibility, pulling requirements and building restrictions belong in the plan. The shortest line on paper can be awkward or unsuitable on site.

Keep each route separately identified if the project has several rooms. This makes a later change easier to discuss without accidentally altering quantities for another part of the installation.

Calculate metres, then packs

The material-length tool adds the route sections you enter. Any extra length should be a visible, deliberate input. Its output does not select the conduit size or approve a number of wires.

For example, suppose a checked route requires 12.6 metres and you explicitly add 1.4 metres for agreed connections and spare material. The total is 14 metres. With two-metre lengths, seven lengths are the arithmetic minimum. A cutting plan may require more if the necessary sections cannot be obtained from those pieces.

Count conductors separately from the conductor schedule. One metre of conduit does not automatically mean one metre of wire, or a standard three metres of wire. Different parts of the route can have different requirements.

Include the rest of the system

ItemQuantity basis
Conduit of the specified constructionRoute, connection allowances and cutting plan determine metres or lengths.
Couplers and bendsCount from the detailed route.
Supports and fixingsMatch the substrate and system installation instructions.
Boxes and entriesMatch the connection points and selected diameters.
Specified conductorsListed separately by function and route.
Cutting, bending and pulling toolsOnly those required by the selected system and installer.

Compare conduit products at KARWEI and check the matching accessories. Attema lists specific entry sizes for its U50 Klemvast box; another box can have different interfaces.

Frequently asked questions

Is 19 mm always the better choice?

No. Extra space can help, but the mounting, interfaces and complete route still need to fit. The design determines the product.

Can any plastic hose protect loose installation wires?

Use an electrical containment system suitable for the application. A hose with the same dimensions does not automatically have the required properties.

Does the calculator assess conduit fill?

No. It adds material lengths from your entries. Permissible fill and electrical suitability need separate technical assessment.

Would you like the route checked before building work begins? Share your sketch with CAS and say which walls remain open. Conduit and conductor choices can then be considered together.

Outside diameter in mm and copper cross-section in mm² are different measurements
Outside diameter in mm and copper cross-section in mm² are different measurements

Materials and specifications

Before buying, check that the size, type and specification suit your installation. Use the article list and tools to work out the quantities you need.

Tape measure and plan

Tape measure
Illustration
Quantity and unit
One tape measure and current plan
Specification
Survey accessible surfaces only; measurements do not establish electrical suitability.

Electrical conduit

Specified by the electrician
Quantity and unit
Measured route plus agreed allowances and checked cutting plan
Specification
Exact system, nominal/inside dimensions, fittings, pullability and thermal design; prewired variants are not automatically interchangeable.
  • KARWEI · Elektriciteitsbuizen
    View range
  • KARWEI · Martens elektrabuis wit 16 mm, 2 meter
    View product
  • KARWEI · Handson voorbedrade buis 16 mm, 3 × 2,5 mm², 12,5 meter
    View product

Plan route quantities

Keep each material, colour and cross-section separate. Specification is still required. A total is not a cutting plan, continuous reel length or conduit-fill calculation. Allowances and contingency are your planning choices, not installation rules.

Worked example and formula

4.2 + 2.8 + 1.5 m plus two 0.3 m allowances = 9.1 m. With a user-chosen 10% contingency: 10.01 m. A 4 m light line and 1.2 m supply route stay separate.

planned m = (sum of measured m + explicit allowances m) × (1 + contingency / 100)

Formula version 2026-10-05.1

Material route 1
Stays on this device during this visit.

One length per line, in metres (0–1000 m). Do not separate a list with commas.

Stays on this device during this visit.
Stays on this device during this visit.
For example 2.5. Up to 2 decimal places; no thousands separators.

Sources

Would you like CAS to carry out the work?

Tell us about the room, equipment and changes you need. Agree the work, checks and warranty terms before the job starts.

Discuss the work

In the event of fire or immediate danger: move to safety and call 112. Do not wait for a form reply.