What this guide covers
In Dutch shops, a joining connector is often described as a lasklem. You can inventory parts for an agreed job. Identifying, disconnecting and joining conductors in a fixed installation requires a competent person, safe isolation and verification of the completed work.
A multi-position connector can electrically join the inserted conductors together. Never assume that three openings provide separate terminals for line, neutral and protective earth. The internal connection and intended use must be understood first. Make sure the packaging and instructions refer to the same product. Buy from an identifiable seller and keep the model information. Do not reuse a damaged, distorted or unidentifiable connector from a box of mixed leftovers. There must also be adequate space for the connectors and conductors. A lid, suitable entries and any required strain relief belong in the assessment. Do not force extra connectors into a box because its cover can still be closed.

Copy or print your summary
In Dutch shops, a joining connector is often described as a lasklem. You can inventory parts for an agreed job. Identifying, disconnecting and joining conductors in a fixed installation requires a competent person, safe isolation and verification of the completed work.
Start with the conductor
Solid, stranded and fine-stranded conductors are different selection categories. A connector suitable for one is not automatically suitable for another. Conductor material and cross-sectional area also matter.
WAGO describes different versions and applications within the 221 series. That information does not apply to every item sold under the WAGO name or every connector with a lever.
A shop may state “up to 4 mm²” while the detailed conditions differ by conductor type. The exact model's manufacturer data determines its permitted range. Also establish how many conductors the agreed design needs to join.
Openings do not form a wiring diagram
A multi-position connector can electrically join the inserted conductors together. Never assume that three openings provide separate terminals for line, neutral and protective earth. The internal connection and intended use must be understood first.
The number of connectors in an old installation is not a design specification either. Have unidentified connections, unexpected conductor colours or multiple circuits in the same area assessed before alteration. A photograph can record what was there but cannot verify it.
Check these details
| Detail | Reason to check |
|---|---|
| Exact model and series | Similar housings can provide different arrangements. |
| Conductor type and material | Solid, stranded and fine-stranded are distinct selection details. |
| Cross-section range | Both lower and upper limits must suit the conductor. |
| Connection positions and internal arrangement | These determine which conductors the product joins. |
| Strip length | A model-specific instruction, not a universal value. |
| Electrical and environmental conditions | The application must remain within the product's limits. |
| Enclosure and mounting | The complete connection needs suitable protection. |
Make sure the packaging and instructions refer to the same product. Buy from an identifiable seller and keep the model information. Do not reuse a damaged, distorted or unidentifiable connector from a box of mixed leftovers.
The connector is one part of the assembly
The installer selects suitable stripping equipment and avoids damaging the conductor. A tool adjusted by diameter uses a different measurement from a conductor specification in mm². The required stripping length comes from the connector instructions.
There must also be adequate space for the connectors and conductors. A lid, suitable entries and any required strain relief belong in the assessment. Do not force extra connectors into a box because its cover can still be closed.
Specific products are available for moisture protection. WAGO describes gelboxes and specifies use within a junction box for 230 V applications. An individual IP-rated item does not by itself establish a complete outdoor or underground installation.
Count the correct types before calculating packs
Create a separate line for each confirmed connector model. The pack calculator deducts suitable stock you already own and rounds the remaining requirement up to complete packs.
For example, suppose an agreed plan requires seven connectors of one exact type and you have no matching stock. If the current pack contains five, you need two packs and will have three spare. This arithmetic does not establish how many connectors a light fitting or socket needs.
Include only the associated parts required by the plan:
- the specified connector types;
- suitable boxes, lids and entries;
- prescribed mounting adaptors or strain relief;
- appropriate stripping and hand tools for the installer;
- an approved moisture-protection arrangement where required.
After selecting the model, compare WAGO 221-413 at Elektramat with other checked offers for that exact product. Toolstation lists stripping tools for comparison. Check whether the offered pack is larger than your project requires.
Frequently asked questions
Are all lever connectors interchangeable?
No. Check the model, conductors, size range, internal connection and application conditions.
Can I use one stripping length for every connector?
No. Follow the exact model's instruction. Too much or too little exposed copper can produce an incorrect connection.
Can a connector lie loose above a ceiling?
Have the full connection and its protection assessed. Selecting a suitable connector alone is insufficient.
Unsure about existing connections? Describe the planned alteration to CAS. Do not open a box to take a photograph; start by explaining the work you want done.
Materials and specifications
Before buying, check that the size, type and specification suit your installation. Use the article list and tools to work out the quantities you need.
Manuals and model details
- Quantity and unit
- One current manual per exact product
- Specification
- Use exact model/revision, with conflicting instructions unresolved until manufacturer/installer clarification.
Wire connector
Specified by the electrician- Quantity and unit
- From designed junctions; poles are not pack quantities
- Specification
- Exact connector model, conductor type/range, strip length, rating, enclosure and environment.
- Elektramat · WAGO 221-413 lasklem 3-voudig, verpakking 50 stuks
View product - Praxis · Wago lasklem hersluitbaar 5-voudig, 6 stuks
View product - Praxis · WAGO lasklem 3-voudig 0,5–2,5 mm², 10 stuks
View product - Praxis · Verbindingsklemmen
View range
Box and matching entries
Specified by the electrician- Quantity and unit
- From specified points/junctions
- Specification
- Box dimensions, mounting, access, entry sizes, completed-system protection and conductor space.
- Elektramat · Attema lasdoos 16 mm wit, 4 invoeren (AT2201)
View product - Elektramat · Attema kabeldoos met wartel M25 IP65 (AT2500)
View product - KARWEI · Elektradozen
View range
Wire stripper
Specified by the electrician
- Quantity and unit
- One suitable model for the specified conductor and insulation
- Specification
- Type/range, blade settings and undamaged conductor outcome; not a competence substitute.
- BAUHAUS · Alpha Tools striptang, automatische aanpassing
View product - GAMMA · Striptangen
View range - Toolstation · Draadstriptangen
View range - Toolstation · Knipex 1105 draadstriptang, 160 mm
View product
Count retail packs
Enter only confirmed compatible, usable stock. Check the actual pack contents; connector positions are not pack quantities. Calculate each variant separately. This is not a cutting plan.
Worked example and formula
17 units required, 2 compatible units owned, 10 per pack: 2 packs, 20 purchased and 5 remaining.
needed = max(0, required − usable owned); packs = ceil(needed / pack size)
Formula version 2026-10-05.1
Sources
Would you like CAS to carry out the work?
Tell us about the room, equipment and changes you need. Agree the work, checks and warranty terms before the job starts.
Discuss the workIn the event of fire or immediate danger: move to safety and call 112. Do not wait for a form reply.